أحادي الطور

CA168-MJ02

Prepaid Dual-source Single-phase Keypad Smart Meter

The CA168-MJ02 is a new generation single-phase multi-function meter with modular design. The meter is used to measure electrical energy accurately for commercial and residential customers. The meter has a wide range of functions and the possibility of intelligent measurement, and its flexible communication module instrument can provide remote management and reading of various communication media.
تحدث عبر واتساب
مقدمة

مقدمة

الميزات الرئيسية

  • Dual relay.
  • Multi tariff
  • DLMS/COESM
  • Infrared port/RS485
  • Tamper detection and record
  • LCD display, read without power
  • Double CT for Phase and Neutral line
  • Disconnects on overload and no credit
  • Prepayment/post-payment mode switching
  • Plug& Play module PLC/GPRS/3G/4G/RF
  • Programmable load limit & Low credit warning
  • Active/reactive energy measurement

Split Configuration for Increased Revenue Protection

The CIU (Customer Interface Unit) is optional. The MCU (Metering & Control Unit) and CIU is linked via Mbus 2 wires communication, galvanically-isolated PLC or RF wireless communication, the communication method is on request.

The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.

Parameters

Electrical parameters:VoltageNominal voltage Un230VLimited voltage70%~120%UnFrequencyNominal frequency fn50-60Hztolerance5%CurrentBasic current(Ib)5AMaximum current(Imax)60A (100A optional)Starting current(Ist)0.4%IbActive energy constant1000imp/kWhMeasurement AccuracyActive energy to IEC62053-21Class1.0BurdenVoltage circuit<2W <8VACurrent circuit<1VATemperature rangeOperation meter-25℃ to+70℃Storage-40℃ to+85℃InsulationInsulation level4kV rms 1minVoltage impulse withstand8kV 1.2/50 μsInsulation System ClassificationProtective Class IIElectro Magnetic CompatibilityElectrostatic dischargesContact discharge8kVAir discharge16kVElectromagnetic RF fields27MHz to 500MHz typical10V/m100kHz to 1GHz typical30V/mFast transient burst test4kVMechanical requirementsMeter shell Protection RateIP54Insulation System ClassificationProtective Class IIMaximum cable size8 mm

المواصفات

Nominal voltage Un
230V
Limited voltage
70% ~ 120%Un
Nominal frequency fn
50~60Hz
Tolerance
±5%
Basic current(lb)
5A
Maximum current(lmax)
60A (80/100A optional)
Starting current(ist)
20mA
Active energy constant
1000imp/kwh
Active energy as IEC62053-21
class 1.0
voltage circuit
<2w <8VA
current circuit
<1VA
operation range
-25c~+70c
storage range
-40c~+85c
Insulation level
4kv rms 1min
Impulse withstand voltage ing
8kv1.2/50us
Insulation system classification
protection class Il
contact discharge
8kv
Air discharge
15kv
27MHz to500MHz typical
10v/m
100KHz to1GHz typical
30v/m
Fast transient burst test
4kv
Meter case protection class
IP54
Maximum cable size
8 mm

معلومات التجارة

المنشأ
Shenzhen, China
العلامة التجارية
CALIN

التطبيقات

  • Residential and commercial electricity metering
  • Utility revenue protection and AMI projects

هل تهتم بمنتجاتنا؟

فريق المبيعات المحترف لدينا بانتظار استشارتك.