Componentes

CT

CT

CT 5(10)A/2mA class0.1 33R 53*22*30
Conversar no WhatsApp
Introdução

Introdução

Product Details

Dimensions: MM

CT dimensions

Product Parameter:

Rated Primary Current5A (r.m.s)
Rated Secondary Current2mA (r.m.s)
Error Nonlinearity0.1
Overload ratio33
Frequency50/60
Withstanding Volt4000(r.m.s)(1mA 1min 50Hz)
Insulation Resistance1000 (Dc 1000V)
Load Resistance33

Electrical Performance Requirements

Primary: Lead out by copper conductor.

Secondary: Lead out by UL1007 #24 Black and Red Wires.

Keep the secondary coil open, then input 10A(rms) current to the primary coil for one minute; the insulation between turns of CT should be without damage.

The CT should withstand an impulse voltage of 8KV under IEC standards.

The accuracy of the CT should not be changed by an over current of 3000A RMS applied for half cycle at 50Hz.