Single phase

CA168-MJ62

Single-Phase Split-Type Prepayment Energy Meter

The CA168-MJ62 is a new generation single-phase multi-function meter with modular design. The meter is used to measure electrical energy accurately for commercial and residential customers. The meter has a wide range of functions and the possibility of intelligent measurement, and its flexible communication module instrument can provide remote management and reading of various communication media.
Introduction

Introduction

Split Configuration for Increased Revenue Protection

The CIU (Customer Interface Unit) is optional. The MCU (Metering & Control Unit) and CIU is linked via Mbus 2 wires communication, galvanically-isolated PLC or RF wireless communication, the communication method is on request.

The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.

Parameters

Electrical parameters:
Voltage
Nominal voltage Un230V
Limited voltage70%~120%Un
Frequency
Nominal frequency fn50-60Hz
tolerance5%
Current
Basic current(Ib)5A
Maximum current(Imax)60A (100A optional)
Starting current(Ist)0.4%Ib
Active energy constant1000imp/kWh
Measurement Accuracy
Active energy to IEC62053-21Class1.0
Burden
Voltage circuit<2W <8VA
Current circuit<1VA
Temperature range
Operation meter-25℃to+70℃
Storage-40℃to+85℃
Insulation
Insulation level4kV rms 1min
Voltage impulse withstand8kV 1.2/50μs
Insulation System ClassificationProtective Class II
Electro Magnetic Compatibility
Electrostatic discharges
Contact discharge8kV
Air discharge16kV
Electromagnetic RF fields
27MHz to 500MHz typical10V/m
100kHz to 1GHz typical30V/m
Fast transient burst test4kV
Mechanical requirements
Meter shell Protection RateIP54
Insulation System ClassificationProtective Class II
Maximum cable size8 mm

Key Features

  • Dual relay.
  • Multi tariff
  • DLMS/COESM
  • Infrared port/RS485
  • Tamper detection and record
  • LCD display, read without power
  • Double CT for Phase and Neutral line
  • Disconnects on overload and no credit
  • Prepayment/post-payment mode switching
  • Plug& Play module PLC/GPRS/3G/4G/RF
  • Programmable load limit & Low credit warning
  • Active/reactive energy measurement

Specifications

Nominal voltage
230V
Frequency
50-60Hz
Accuracy
Class 1.0
Protection
IP54
Metering system
Single-phase

Trade information

Origin
Shenzhen, China
Brand
CALIN

Applications

  • Residential and commercial electricity metering
  • Utility revenue protection and AMI projects

Have a project in mind?

Share your utility requirements, target market and expected quantity. Our metering team will respond with the right product and integration path.