Monofásico

CA168-SF01

Single-Phase DIN-Rail Smart Meter

CA168-SF01 is our new generation of Din-rail single-phase electricity meter, with accuracy of Class 1,and its shell is made of polycarbonate flame retardant material.This meter is equipped with a current isolation wire and also supports dual circuit measurement and relays to bring outstanding tamper detection features. The communication with the external keypad(ClU) can be done with either PLC, RF, or by Cable connection. Its installation requirements are also optional.
Introducción

Introducción

Split Configuration for Increased Revenue Protection

The CIU (Customer Interface Unit) is optional. The MCU (Metering & Control Unit) and CIU is linked via Mbus 2 wires communication, galvanically-isolated PLC or RF wireless communication, the communication method is on request.

The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.

Parameters

Electrical parameters:
Voltage
Nominal voltage Un230V
Limited voltage70%~120%Un
Frequency
Nominal frequency fn50-60Hz
tolerance5%
Current
Basic current(Ib)5A
Maximum current(Imax)60A (100A optional)
Starting current(Ist)0.4%Ib
Active energy constant1000imp/kWh
Measurement Accuracy
Active energy to IEC62053-21Class1.0
Burden
Voltage circuit<2W <8VA
Current circuit<1VA
Temperature range
Operation meter-25℃to+70℃
Storage-40℃to+85℃
Insulation
Insulation level4kV rms 1min
Voltage impulse withstand8kV 1.2/50μs
Insulation System ClassificationProtective Class II
Electro Magnetic Compatibility
Electrostatic discharges
Contact discharge8kV
Air discharge16kV
Electromagnetic RF fields
27MHz to 500MHz typical10V/m
100kHz to 1GHz typical30V/m
Fast transient burst test4kV
Mechanical requirements
Meter shell Protection RateIP54
Insulation System ClassificationProtective Class II
Maximum cable size8 mm

Características principales

  • .Multi-Tariff
  • DLMS/COSEM
  • STS prepayment
  • 20 digits STS encryption
  • Tamper detection and record
  • LoraWan centralized collecting
  • Slim-line and space-economy design
  • Disconnect on overload and no credit
  • Programmable load limit and low credit warning
  • Infrared port/RS485/virtual token carrier(optional)Surge protection for lightening and other line surges
  • Up to 13kV/6.5kA surge protection for lightening and other line surges
  • CIU by PLC/RF/ Cable (optional)

Especificaciones

Nominal voltage
230V
Frequency
50-60Hz
Accuracy
Class 1.0
Protection
IP54
Current
5A, maximum 60A or 80A

Información comercial

Origen
Shenzhen, China
Marca
CALIN

Aplicaciones

  • Residential and commercial electricity metering
  • Utility revenue protection and AMI projects

¿Tiene un proyecto?