Single phase

CA168-SA01

Single-Phase DIN-Rail Energy Meter

The CA168-SA01 is our new generation split compact Din rail meter with class l accuracy.The meter complies with the STS standard and is suitable for commercial and residential customers.The CA168-SA01 has outstanding tamper detection features.The communication with the external keypad(ClU) can be done with either PLC, RF, or by Cable connection. Its installation requirements are also optional.
Introduction

Introduction

Multi-Tariff

DLMS/COSEM

STS prepayment

20 digits STS encryption

35mm Din-rail installation

Tamper detection and record

CIU by PLC/RF/ Cable (optional)

Slim-line and space-economy design

Disconnect on overload and no credit

Programmable load limit and low credit warning

Infrared port/RS485/virtual token carrier (optional)

Surge protection for lightening and other line surges

Split Configuration for Increased Revenue Protection

The CIU (Customer Interface Unit) is optional. The MCU (Metering & Control Unit) and CIU is linked via Mbus 2 wires communication, galvanically-isolated PLC or RF wireless communication, the communication method is on request.

The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.

Parameters

Electrical parameters:
Voltage
Nominal voltage Un230V
Limited voltage70%~120%Un
Frequency
Nominal frequency fn50-60Hz
tolerance5%
Current
Basic current(Ib)5A
Maximum current(Imax)60A (100A optional)
Starting current(Ist)0.4%Ib
Active energy constant1000imp/kWh
Measurement Accuracy
Active energy to IEC62053-21Class1.0
Burden
Voltage circuit<2W <8VA
Current circuit<1VA
Temperature range
Operation meter-25℃ to+70℃
Storage-40℃ to+85℃
Insulation
Insulation level4kV rms 1min
Voltage impulse withstand8kV 1.2/50 μs
Insulation System ClassificationProtective Class II
Electro Magnetic Compatibility
Electrostatic discharges
Contact discharge8kV
Air discharge16kV
Electromagnetic RF fields
27MHz to 500MHz typical10V/m
100kHz to 1GHz typical30V/m
Fast transient burst test4kV
Mechanical requirements
Meter shell Protection RateIP54
Insulation System ClassificationProtective Class II
Maximum cable size8 mm

Specifications

Installation
35mm DIN rail
Nominal voltage
230V
Current
5(60)A
Accuracy
Class 1

Trade information

Origin
Shenzhen, China
Brand
CALIN

Applications

  • Residential and commercial electricity metering
  • Utility revenue protection and AMI projects

Have a project in mind?